Model No.︰MF102
Brand Name︰BRACE
Country of Origin︰China
Unit Price︰CNY ¥ 50 / pc
Minimum Order︰1 pc
MTL Series
Solenoid Dosing Pump
MTL is a simple solenoid dosing pump,
operating with a micro-processor
to manage the dosing, it is easy to opera with stable flow rate.
It has four model :MF,ML
Main features:
Max pressure:10 bar; Max flow rate :9 L/H
Pump head: PVC
Compatibal
PVC pump head and ceramic ball valve as standard
PVC is suitable for almost all chemical used in the industrial ,waste water treatment and potable water applications
the use of ceramic balls as standard improves the pumping reliability and the chemical compatibility of the whole liquid end.
Reliable
Diaphragm _Made of pure solid PTFE
The advanced design and manufacturing process allows the diaphragm to have a unique life expectancy.
Made of pure solid PTFE, the diaphragm is compatible with most chemicals
Routine diaphragm replacement is no longer a requirement
Dosing Model
The flow rate is manually or automatically (by signal input) adjustable,MF, ML ,MC, and MG have level control input.
Liquid end
pump head :PVC
Ball :Ceramic
Seal :FPM/EPDM
Diaphragm :PTFE
Installation
Horizontally-mounted(standard)
Wall-mounted(option, need to buy bracket)
MF : Analogue dosing pump with constant flow rate manually adjustable
Flow rate manually adjustable by control dial on the front panel ,Power-on LED indicator ,with indication of frequency percentage(p%) and stroke number(F)
ML : Analogue dosing pump with constant flow rate manually adjustable and level control input
Flow rate manually adjustable by control dial on the front panel ,power on LED indicator ,with indication of frequency percentage (p%) and stroke number(F),with level control input.
MC: Automatic control (digital pulse signal input)
With operation status indication, level control input, have two dosing models:
Constant The pump doses the rate selected with the button
Proportional The pump doses proportionally to the signal
MG : Automatic control (4-20mA signal input)
With operation status indication, level control input, have two dosing models:
Constant The pump doses the rate selected with the button
Proportional The pump doses proportionally to the signal
Specification
Model
|
Pressure |
Flow Rate |
Frequency Max. |
Stroke Capacity |
φ Connections IN/OUT |
Consumption |
(bar) |
(L/H) |
(stroke/min) |
(cc/stroke) |
(mm) |
(W) |
|
106 |
20 |
0.4 |
120 |
0.38 |
4/6 suc |
40 |
16 |
0.8 |
0.55 |
||||
10 |
1.2 |
0.83 |
||||
6 |
1.5 |
1.00 |
||||
101 |
10 |
1 |
120 |
0.35 |
4/6 suc |
20 |
100 |
10 |
3 |
160 |
0.42 |
4/6 |
20 |
8 |
5 |
0.52 |
||||
2 |
9 |
0.63 |
||||
102 |
16 |
7 |
300 |
0.39 |
4/6 |
40 |
10 |
10 |
0.55 |
||||
5 |
15 |
0.83 |
||||
1 |
20 |
1.00 |
||||
103 |
20 |
5 |
300 |
1.11 |
8/12 |
40 |
32 |
4 |
1.78 |
||||
2 |
62 |
3.44 |
||||
0.1 |
110 |
6.11 |
Application:
Urban water treatment and waste water treatment ,dosing of chlorine dioxide, reverse
osmosis ,food , beverage and pharmacy, etc
Payment Terms︰ TT